new header file for the setup of Visual Basic 6.0 run-time files
git-svn-id: https://svn.code.sf.net/p/nsis/code/NSIS/trunk@5489 212acab6-be3b-0410-9dea-997c60f758d6
This commit is contained in:
parent
23e1474468
commit
858ddb4141
4 changed files with 392 additions and 325 deletions
|
@ -1,302 +1,277 @@
|
|||
\A{library} DLL/TLB Library Setup
|
||||
|
||||
|
||||
\H{library_intro} Introduction
|
||||
|
||||
NSIS 2.01 features a new system for the installation and uninstallation of dynamic link libraries (DLL) and type libraries (TLB).
|
||||
Using this new system you can handle the complete setup with one single line of code:
|
||||
|
||||
\b File copying
|
||||
|
||||
\b File copying on reboot
|
||||
|
||||
\b Version checks
|
||||
|
||||
\b Registration and unregistration
|
||||
|
||||
\b Registration and unregistration on reboot
|
||||
|
||||
\b Shared DLL counting
|
||||
|
||||
\b Windows File Protection checks
|
||||
|
||||
The macros are stored in the header file Library.nsh, which should be included in scripts using this system:
|
||||
|
||||
\c !include Library.nsh
|
||||
|
||||
Note that the library macros are limited on non-Windows platforms. DLL version information is required when compiling on non-Windows platforms.
|
||||
|
||||
|
||||
\H{library_install} Library Installation
|
||||
|
||||
\S1{} Introduction
|
||||
|
||||
The InstallLib macro allows you to install a library. It sets the error flag if something went wrong during library setup.
|
||||
|
||||
To ask the user for a reboot, if required, use the Modern UI with a Finish page or use \R{ifrebootflag}{IfRebootFlag} and make your own page or message box.
|
||||
|
||||
\S1{} Parameters
|
||||
|
||||
\c libtype shared install localfile destfile tempbasedir
|
||||
|
||||
\\<b\\>libtype\\</b\\>
|
||||
|
||||
The type of the library
|
||||
|
||||
DLL - Dynamic link library (DLL)\\<br\\>
|
||||
REGDLL - DLL that has to be registered\\<br\\>
|
||||
TLB - Type library or DLL that contains a type LIBRARY\\<br\\>
|
||||
REGDLLTLB - DLL that has to be registered and contains a type library\\<br\\>
|
||||
|
||||
|
||||
\\<b\\>shared\\</b\\>
|
||||
|
||||
Specify whether the library is shared with other applications
|
||||
|
||||
NOTSHARED - The library is not shared\\<br\\>
|
||||
$VARNAME - Variable that is empty when the application is installed for the first time,
|
||||
which is when the shared library count will be increased.\\<br\\>
|
||||
|
||||
\\<b\\>install\\</b\\>
|
||||
|
||||
Specify the installation method
|
||||
|
||||
REBOOT_PROTECTED
|
||||
|
||||
\b Upgrade the library on reboot when in use (required for system files).
|
||||
|
||||
\b Upgrade the library if the file is not protected by Windows File Protection.
|
||||
|
||||
NOREBOOT_PROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Upgrade the library if the file is not protected by Windows File Protection.
|
||||
|
||||
REBOOT_NOTPROTECTED
|
||||
|
||||
\b Upgrade the library on reboot when in use (required for system files).
|
||||
|
||||
\b Upgrade the library without checking for Windows File Protection.
|
||||
|
||||
NOREBOOT_NOTPROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Upgrade the library without checking for Windows File Protection.
|
||||
|
||||
\\<b\\>localfile\\</b\\>
|
||||
|
||||
Location of the library on the compiler system
|
||||
|
||||
\\<b\\>destfile\\</b\\>
|
||||
|
||||
Location to store the library on the user's system
|
||||
|
||||
\\<b\\>tempbasedir\\</b\\>
|
||||
|
||||
Directory on the user's system to store a temporary file when the system has to be rebooted.
|
||||
|
||||
For Windows 9x/ME support, this directory should be on the same volume as the destination file (destfile).
|
||||
The Windows temp directory could be located on any volume, so you cannot use this directory.
|
||||
|
||||
\S1{} Options
|
||||
|
||||
\R{define}{Define} any of the following before inserting the InstallLib macro to modify its behavior as specified.
|
||||
|
||||
\S2{} LIBRARY_X64
|
||||
|
||||
\b Installs a DLL built for Windows x64.
|
||||
|
||||
\b \\<b\\>Warning:\\</b\\> this resets file system redirection.
|
||||
|
||||
\S2{} LIBRARY_SHELL_EXTENSION
|
||||
|
||||
\b Define this before inserting InstallLib macro to call SHChangeNotify with SHCNE_ASSOCCHANGED after registration.
|
||||
|
||||
\b Use this to refresh the shell when installing a shell extension or when changing file associations.
|
||||
|
||||
\S2{} LIBRARY_COM
|
||||
|
||||
\b Define this before inserting InstallLib macro to call CoFreeUnusedLibraries after registration.
|
||||
|
||||
\b Use this for unloading all unnecessary libraries from memory when installing COM libraries.
|
||||
|
||||
\S2{} LIBRARY_IGNORE_VERSION
|
||||
|
||||
\b Define this before inserting InstallLib macro to ignore version information in the file and always install it, even if it already exists.
|
||||
|
||||
\b Use this when an older or specific version is required.
|
||||
|
||||
\b Not recommended for DLLs installed to $SYSDIR.
|
||||
|
||||
\S1{} Notes
|
||||
|
||||
\b If you want to support Windows 9x/ME, you can only use short filenames (8.3).
|
||||
|
||||
\b \\<b\\>Warning:\\</b\\> when deploying DLLs, always use redistributable files. Never copy files from your system directory.
|
||||
|
||||
\S1{} Example
|
||||
|
||||
\S2{} Unshared DLL
|
||||
|
||||
\c !insertmacro InstallLib REGDLL NOTSHARED REBOOT_NOTPROTECTED dllname.dll $SYSDIR\dllname.dll $SYSDIR
|
||||
|
||||
\S2{} Shared DLL
|
||||
|
||||
\c ;Add code here that sets $ALREADY_INSTALLED to a non-zero value if the application is
|
||||
\c ;already installed. For example:
|
||||
\c
|
||||
\c IfFileExists "$INSTDIR\MyApp.exe" 0 new_installation ;Replace MyApp.exe with your application filename
|
||||
\c StrCpy $ALREADY_INSTALLED 1
|
||||
\c new_installation:
|
||||
\c
|
||||
\c !insertmacro InstallLib REGDLL $ALREADY_INSTALLED REBOOT_NOTPROTECTED dllname.dll $SYSDIR\dllname.dll $SYSDIR
|
||||
|
||||
\H{library_uninstall} Library Uninstallation
|
||||
|
||||
\S1{} Introduction
|
||||
|
||||
The UnInstallLib macro allows you to uninstall a library. It sets the error flag if something went wrong during library removal.
|
||||
|
||||
\S1{} Parameters
|
||||
|
||||
\c libtype shared uninstall file
|
||||
|
||||
\\<b\\>libtype\\</b\\>
|
||||
|
||||
The type of the library
|
||||
|
||||
DLL - Dynamic link library (DLL)\\<br\\>
|
||||
REGDLL - DLL that has to be registered\\<br\\>
|
||||
TLB - Type library or DLL that contains a type LIBRARY\\<br\\>
|
||||
REGDLLTLB - DLL that has to be registered and contains a type library\\<br\\>
|
||||
|
||||
|
||||
\\<b\\>shared\\</b\\>
|
||||
|
||||
Specify whether the library is shared with other applications
|
||||
|
||||
NOTSHARED - The library is not shared\\<br\\>
|
||||
SHARED - The library is shared and should be removed if the shared library count
|
||||
indicates that the file is not in use anymore..\\<br\\>
|
||||
|
||||
\\<b\\>uninstall\\</b\\>
|
||||
|
||||
Specify the uninstallation method
|
||||
|
||||
NOREMOVE
|
||||
|
||||
\b The library should not be removed. You should use this option for common or important
|
||||
system files such as the Visual Basic/C++/MFC runtimes.
|
||||
|
||||
REBOOT_PROTECTED
|
||||
|
||||
\b Remove the library on reboot when in use (required for system files).
|
||||
|
||||
\b Remove the library if the file is not protected by Windows File Protection.
|
||||
|
||||
NOREBOOT_PROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Remove the library if the file is not protected by Windows File Protection.
|
||||
|
||||
REBOOT_NOTPROTECTED
|
||||
|
||||
\b Remove the library on reboot when in use (required for system files).
|
||||
|
||||
\b Remove the library without checking for Windows File Protection.
|
||||
|
||||
NOREBOOT_NOTPROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Remove the library without checking for Windows File Protection.
|
||||
|
||||
|
||||
\\<b\\>file\\</b\\>
|
||||
|
||||
Location of the library
|
||||
|
||||
\S1{} Options
|
||||
|
||||
\R{define}{Define} any of the following before inserting the UnInstallLib macro to modify its behavior as specified.
|
||||
|
||||
\S2{} LIBRARY_X64
|
||||
|
||||
\b Uninstalls a DLL built for Windows x64.
|
||||
|
||||
\b \\<b\\>Warning:\\</b\\> this resets \R{setregview}{RegSetView} and file system redirection.
|
||||
|
||||
\S2{} LIBRARY_SHELL_EXTENSION
|
||||
|
||||
\b Define this before inserting UninstallLib macro to call SHChangeNotify with SHCNE_ASSOCCHANGED after unregistration. Use this to refresh the shell when uninstalling a shell extension or when changing file associations.
|
||||
|
||||
\S2{} LIBRARY_COM
|
||||
|
||||
\b Define this before inserting UninstallLib macro to call CoFreeUnusedLibraries after unregistration. Use this for unloading all unnecessary libraries from memory when uninstalling COM libraries.
|
||||
|
||||
\S1{} Example
|
||||
|
||||
\c !insertmacro UnInstallLib REGDLL SHARED REBOOT_NOTPROTECTED $SYSDIR\dllname.dll
|
||||
|
||||
|
||||
\H{library_vb6} Visual Basic 6 Runtimes
|
||||
|
||||
Add this code to your script to install and uninstall the VB6 runtimes.
|
||||
|
||||
The correct version of the following files should be stored in your script folder
|
||||
(or modify the paths to the local files if you want to use another folder):
|
||||
|
||||
\b msvbvm60.dll
|
||||
|
||||
\b oleaut32.dll
|
||||
|
||||
\b olepro32.dll
|
||||
|
||||
\b oleaut32.dll
|
||||
|
||||
\b comcat.dll
|
||||
|
||||
\b asycfilt.dll
|
||||
|
||||
\b stdole2.tlb
|
||||
|
||||
A \W{http://support.microsoft.com/default.aspx?scid=kb;en-us;290887}{Microsoft article} that explains how to obtain these files is available.
|
||||
|
||||
To ask the user for a reboot, if required, use the Modern UI with a Finish page or use \R{ifrebootflag}{IfRebootFlag} and make your own page or message box.
|
||||
|
||||
\c !include Library.nsh
|
||||
\c
|
||||
\c Var ALREADY_INSTALLED
|
||||
\c
|
||||
\c Section "-Install VB6 runtimes"
|
||||
\c
|
||||
\c ;Add code here that sets $ALREADY_INSTALLED to a non-zero value if the application is already installed. For example:
|
||||
\c
|
||||
\c IfFileExists "$INSTDIR\MyApp.exe" 0 new_installation ;Replace MyApp.exe with your application filename
|
||||
\c StrCpy $ALREADY_INSTALLED 1
|
||||
\c new_installation:
|
||||
\c
|
||||
\c !insertmacro InstallLib REGDLL $ALREADY_INSTALLED REBOOT_NOTPROTECTED "msvbvm60.dll" "$SYSDIR\msvbvm60.dll" "$SYSDIR"
|
||||
\c !insertmacro InstallLib REGDLL $ALREADY_INSTALLED REBOOT_PROTECTED "oleaut32.dll" "$SYSDIR\oleaut32.dll" "$SYSDIR"
|
||||
\c !insertmacro InstallLib REGDLL $ALREADY_INSTALLED REBOOT_PROTECTED "olepro32.dll" "$SYSDIR\olepro32.dll" "$SYSDIR"
|
||||
\c !insertmacro InstallLib REGDLL $ALREADY_INSTALLED REBOOT_PROTECTED "comcat.dll" "$SYSDIR\comcat.dll" "$SYSDIR"
|
||||
\c !insertmacro InstallLib DLL $ALREADY_INSTALLED REBOOT_PROTECTED "asycfilt.dll" "$SYSDIR\asycfilt.dll" "$SYSDIR"
|
||||
\c !insertmacro InstallLib TLB $ALREADY_INSTALLED REBOOT_PROTECTED "stdole2.tlb" "$SYSDIR\stdole2.tlb" "$SYSDIR"
|
||||
\c
|
||||
\c SectionEnd
|
||||
\c
|
||||
\c Section "-un.Uninstall VB6 runtimes"
|
||||
\c
|
||||
\c !insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\msvbvm60.dll"
|
||||
\c !insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\oleaut32.dll"
|
||||
\c !insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\olepro32.dll"
|
||||
\c !insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\comcat.dll"
|
||||
\c !insertmacro UnInstallLib DLL SHARED NOREMOVE "$SYSDIR\asycfilt.dll"
|
||||
\c !insertmacro UnInstallLib TLB SHARED NOREMOVE "$SYSDIR\stdole2.tlb"
|
||||
\c
|
||||
\c SectionEnd
|
||||
|
||||
You can use similar code to install common VB6 ActiveX controls (such as the controls for Windows Common Controls).
|
||||
\A{library} DLL/TLB Library Setup
|
||||
|
||||
|
||||
\H{library_intro} Introduction
|
||||
|
||||
The Library header file can be used to setup dynamic link libraries (DLL) and type libraries (TLB).
|
||||
If necessary, the following actions will be performed:
|
||||
|
||||
\b File copying
|
||||
|
||||
\b File copying on reboot
|
||||
|
||||
\b Version checks
|
||||
|
||||
\b Registration and unregistration
|
||||
|
||||
\b Registration and unregistration on reboot
|
||||
|
||||
\b Shared DLL counting
|
||||
|
||||
\b Windows File Protection checks
|
||||
|
||||
The macros are stored in the header file Library.nsh, which should be included in scripts using this system:
|
||||
|
||||
\c !include Library.nsh
|
||||
|
||||
Note that the library macros are limited on non-Windows platforms. DLL version information is required when compiling on non-Windows platforms.
|
||||
|
||||
|
||||
\H{library_install} Library Installation
|
||||
|
||||
\S1{} Introduction
|
||||
|
||||
The InstallLib macro allows you to install a library. It sets the error flag if something went wrong during library setup.
|
||||
|
||||
To ask the user for a reboot, if required, use the Modern UI with a Finish page or use \R{ifrebootflag}{IfRebootFlag} and make your own page or message box.
|
||||
|
||||
\S1{} Parameters
|
||||
|
||||
\c libtype shared install localfile destfile tempbasedir
|
||||
|
||||
\\<b\\>libtype\\</b\\>
|
||||
|
||||
The type of the library
|
||||
|
||||
DLL - Dynamic link library (DLL)\\<br\\>
|
||||
REGDLL - DLL that has to be registered\\<br\\>
|
||||
TLB - Type library or DLL that contains a type LIBRARY\\<br\\>
|
||||
REGDLLTLB - DLL that has to be registered and contains a type library\\<br\\>
|
||||
|
||||
|
||||
\\<b\\>shared\\</b\\>
|
||||
|
||||
Specify whether the library is shared with other applications
|
||||
|
||||
NOTSHARED - The library is not shared\\<br\\>
|
||||
$VARNAME - Variable that is empty when the application is installed for the first time,
|
||||
which is when the shared library count will be increased.\\<br\\>
|
||||
|
||||
\\<b\\>install\\</b\\>
|
||||
|
||||
Specify the installation method
|
||||
|
||||
REBOOT_PROTECTED
|
||||
|
||||
\b Upgrade the library on reboot when in use (required for system files).
|
||||
|
||||
\b Upgrade the library if the file is not protected by Windows File Protection.
|
||||
|
||||
NOREBOOT_PROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Upgrade the library if the file is not protected by Windows File Protection.
|
||||
|
||||
REBOOT_NOTPROTECTED
|
||||
|
||||
\b Upgrade the library on reboot when in use (required for system files).
|
||||
|
||||
\b Upgrade the library without checking for Windows File Protection.
|
||||
|
||||
NOREBOOT_NOTPROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Upgrade the library without checking for Windows File Protection.
|
||||
|
||||
\\<b\\>localfile\\</b\\>
|
||||
|
||||
Location of the library on the compiler system
|
||||
|
||||
\\<b\\>destfile\\</b\\>
|
||||
|
||||
Location to store the library on the user's system
|
||||
|
||||
\\<b\\>tempbasedir\\</b\\>
|
||||
|
||||
Directory on the user's system to store a temporary file when the system has to be rebooted.
|
||||
|
||||
For Windows 9x/ME support, this directory should be on the same volume as the destination file (destfile).
|
||||
The Windows temp directory could be located on any volume, so you cannot use this directory.
|
||||
|
||||
\S1{} Options
|
||||
|
||||
\R{define}{Define} any of the following before inserting the InstallLib macro to modify its behavior as specified.
|
||||
|
||||
\S2{} LIBRARY_X64
|
||||
|
||||
\b Installs a DLL built for Windows x64.
|
||||
|
||||
\b \\<b\\>Warning:\\</b\\> this resets file system redirection.
|
||||
|
||||
\S2{} LIBRARY_SHELL_EXTENSION
|
||||
|
||||
\b Define this before inserting InstallLib macro to call SHChangeNotify with SHCNE_ASSOCCHANGED after registration.
|
||||
|
||||
\b Use this to refresh the shell when installing a shell extension or when changing file associations.
|
||||
|
||||
\S2{} LIBRARY_COM
|
||||
|
||||
\b Define this before inserting InstallLib macro to call CoFreeUnusedLibraries after registration.
|
||||
|
||||
\b Use this for unloading all unnecessary libraries from memory when installing COM libraries.
|
||||
|
||||
\S2{} LIBRARY_IGNORE_VERSION
|
||||
|
||||
\b Define this before inserting InstallLib macro to ignore version information in the file and always install it, even if it already exists.
|
||||
|
||||
\b Use this when an older or specific version is required.
|
||||
|
||||
\b Not recommended for DLLs installed to $SYSDIR.
|
||||
|
||||
\S1{} Notes
|
||||
|
||||
\b If you want to support Windows 9x/ME, you can only use short filenames (8.3).
|
||||
|
||||
\b \\<b\\>Warning:\\</b\\> when deploying DLLs, always use redistributable files. Never copy files from your system directory.
|
||||
|
||||
\S1{} Example
|
||||
|
||||
\S2{} Unshared DLL
|
||||
|
||||
\c !insertmacro InstallLib REGDLL NOTSHARED REBOOT_NOTPROTECTED dllname.dll $SYSDIR\dllname.dll $SYSDIR
|
||||
|
||||
\S2{} Shared DLL
|
||||
|
||||
\c ;Add code here that sets $ALREADY_INSTALLED to a non-zero value if the application is
|
||||
\c ;already installed. For example:
|
||||
\c
|
||||
\c IfFileExists "$INSTDIR\MyApp.exe" 0 new_installation ;Replace MyApp.exe with your application filename
|
||||
\c StrCpy $ALREADY_INSTALLED 1
|
||||
\c new_installation:
|
||||
\c
|
||||
\c !insertmacro InstallLib REGDLL $ALREADY_INSTALLED REBOOT_NOTPROTECTED dllname.dll $SYSDIR\dllname.dll $SYSDIR
|
||||
|
||||
\H{library_uninstall} Library Uninstallation
|
||||
|
||||
\S1{} Introduction
|
||||
|
||||
The UnInstallLib macro allows you to uninstall a library. It sets the error flag if something went wrong during library removal.
|
||||
|
||||
\S1{} Parameters
|
||||
|
||||
\c libtype shared uninstall file
|
||||
|
||||
\\<b\\>libtype\\</b\\>
|
||||
|
||||
The type of the library
|
||||
|
||||
DLL - Dynamic link library (DLL)\\<br\\>
|
||||
REGDLL - DLL that has to be registered\\<br\\>
|
||||
TLB - Type library or DLL that contains a type LIBRARY\\<br\\>
|
||||
REGDLLTLB - DLL that has to be registered and contains a type library\\<br\\>
|
||||
|
||||
|
||||
\\<b\\>shared\\</b\\>
|
||||
|
||||
Specify whether the library is shared with other applications
|
||||
|
||||
NOTSHARED - The library is not shared\\<br\\>
|
||||
SHARED - The library is shared and should be removed if the shared library count
|
||||
indicates that the file is not in use anymore..\\<br\\>
|
||||
|
||||
\\<b\\>uninstall\\</b\\>
|
||||
|
||||
Specify the uninstallation method
|
||||
|
||||
NOREMOVE
|
||||
|
||||
\b The library should not be removed. You should use this option for common or important
|
||||
system files such as the Visual Basic/C++/MFC runtimes.
|
||||
|
||||
REBOOT_PROTECTED
|
||||
|
||||
\b Remove the library on reboot when in use (required for system files).
|
||||
|
||||
\b Remove the library if the file is not protected by Windows File Protection.
|
||||
|
||||
NOREBOOT_PROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Remove the library if the file is not protected by Windows File Protection.
|
||||
|
||||
REBOOT_NOTPROTECTED
|
||||
|
||||
\b Remove the library on reboot when in use (required for system files).
|
||||
|
||||
\b Remove the library without checking for Windows File Protection.
|
||||
|
||||
NOREBOOT_NOTPROTECTED
|
||||
|
||||
\b Warns the user when the library is in use. The user will have to close applications using the library.
|
||||
|
||||
\b Remove the library without checking for Windows File Protection.
|
||||
|
||||
|
||||
\\<b\\>file\\</b\\>
|
||||
|
||||
Location of the library
|
||||
|
||||
\S1{} Options
|
||||
|
||||
\R{define}{Define} any of the following before inserting the UnInstallLib macro to modify its behavior as specified.
|
||||
|
||||
\S2{} LIBRARY_X64
|
||||
|
||||
\b Uninstalls a DLL built for Windows x64.
|
||||
|
||||
\b \\<b\\>Warning:\\</b\\> this resets \R{setregview}{RegSetView} and file system redirection.
|
||||
|
||||
\S2{} LIBRARY_SHELL_EXTENSION
|
||||
|
||||
\b Define this before inserting UninstallLib macro to call SHChangeNotify with SHCNE_ASSOCCHANGED after unregistration. Use this to refresh the shell when uninstalling a shell extension or when changing file associations.
|
||||
|
||||
\S2{} LIBRARY_COM
|
||||
|
||||
\b Define this before inserting UninstallLib macro to call CoFreeUnusedLibraries after unregistration. Use this for unloading all unnecessary libraries from memory when uninstalling COM libraries.
|
||||
|
||||
\S1{} Example
|
||||
|
||||
\c !insertmacro UnInstallLib REGDLL SHARED REBOOT_NOTPROTECTED $SYSDIR\dllname.dll
|
||||
|
||||
|
||||
\H{library_vb6} Visual Basic 6 Run-Time Files
|
||||
|
||||
A new VB6.nsh header file is available for the setup of the VB6 run-time files.
|
||||
To obtain the latest run-time files, download \W{http://nsis.sourceforge.net/vb6runtime.zip} and extract this file.
|
||||
|
||||
\c !include VB6RunTime.nsh
|
||||
\c
|
||||
\c Var AlreadyInstalled
|
||||
\c
|
||||
\c Section "-Install VB6 run-time files"
|
||||
\c
|
||||
\c ;Add code here that sets $AlreadyInstalled to a non-zero value if the application is already installed. For example:
|
||||
\c IfFileExists "$INSTDIR\MyApp.exe" 0 new_installation ;Replace MyApp.exe with your application filename
|
||||
\c StrCpy $AlreadyInstalled 1
|
||||
\c new_installation:
|
||||
\c
|
||||
\c !insertmacro VB6RunTimeInstall C:\vb6runtimes $AlreadyInstalled ;Replace C:\vb6runtimes with the location of the files
|
||||
\c
|
||||
\c SectionEnd
|
||||
\c
|
||||
\c Section "-un.Uninstall VB6 run-time files"
|
||||
\c
|
||||
\c !insertmacro VB6RunTimeUnInstall
|
||||
\c
|
||||
\c SectionEnd
|
||||
|
||||
Remarks:
|
||||
|
||||
\b You may have to install additional files for such Visual Basic application to work, such as OCX files for user interface controls.
|
||||
|
||||
\b Installation of the run-time files requires Administrator or Power User privileges. Use the Multi-User header file to verify whether these privileges are available.
|
||||
|
||||
\b Add a Modern UI finish page or another check (see \R{ifrebootflag}{IfRebootFlag}) to allow the user to restart the computer when necessary.
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue